Violation Detail
Standard Cited: 19100147 C04 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1427100.015
Citation: 01002
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $13,494.00
Current Penalty: $11,000.00
Issuance Date: 02/21/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 10/14/2022
Gravity: 10
Report ID: 0214200
Contest Date: 03/13/2020
Final Order: 10/14/2020
Related Event Code (REC): R
Emphasis:
Substance: 2260
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 10/14/2020 | $11,000.00 | 10/14/2022 | Other | |
Penalty | C: Contested | 03/23/2020 | $13,494.00 | 03/16/2020 | Serious | |
Penalty | Z: Issued | 02/21/2020 | $13,494.00 | 03/16/2020 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures: Workplace, NJ Route 440 and 22nd Street, Bayonne, NJ a) The employer did not outline specific requirements for testing the machines and equipment to confirm hazardous chemical energy was isolated for employees to safely perform flange slip removals on the 50% Sodium Hydroxide tank line above rail line 7 and 8 outbound loading pipe, and truck rack #2 outbound loading pipe. Violation occurred on or about 8-28-19