Violation Detail
Standard Cited: 19170112 B01 Guarding of edges.
Inspection Nr: 1422313.015
Citation: 01002
Citation Type: Serious
Abatement Date: 11/13/2019 2
Initial Penalty: $8,051.00
Current Penalty: $4,830.60
Issuance Date: 10/17/2019
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0420100
Contest Date:
Final Order: 11/05/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/05/2019 | $4,830.60 | 11/13/2019 | Serious | |
Penalty | Z: Issued | 10/17/2019 | $8,051.00 | 11/13/2019 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1917.112(b)(1): Guardrails were not provided at locations where employees were exposed to floor or wall openings or waterside edges, including bridges or gangway-like structures leading to pilings or vessel mooring or berthing installations, which present a hazard of falling more than 4 feet (1.22 m) or into the water, except as specified in paragraph (b)(2) of this section: a) On or about June 9, 2019 in the maintenance area the employees were exposed to a fall from the mezzanine storage area with a height of 8 foot, 11 inches and the employer did not ensure guardrails were provided at locations where employees were exposed to falling.