Violation Detail
Standard Cited: 19260451 E01 General requirements.
Inspection Nr: 1421673.015
Citation: 01002
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $4,048.00
Current Penalty: $4,048.00
Issuance Date: 01/30/2020
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC): A;I
Gravity: 10
Report ID: 0214500
Contest Date: 08/28/2020
Final Order: 08/12/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 08/12/2021 | $4,048.00 | Serious | ||
Penalty | C: Contested | 09/01/2020 | $4,048.00 | Serious | ||
Penalty | Z: Issued | 01/30/2020 | $4,048.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) Building Exterior-left side: Employees were exposed to a fall hazard while accessing a ladder jack scaffold that was not provided with proper scaffold access. Employees were using the ladders of the ladder jack scaffold and going over the scaffold platform thus being exposed to a fall hazard, on or about 8/8/2019.