Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1421483.015
Citation: 01002
Citation Type: Serious
Abatement Status:
Initial Penalty: $13,260.00
Current Penalty: $0.00
Issuance Date: 09/16/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 10/09/2019
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 10/10/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/10/2019 | $0.00 | 10/09/2019 | Serious | |
| Penalty | Z: Issued | 09/16/2019 | $13,260.00 | 10/09/2019 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: Schwan's MaMa Rosas LLC in Sidney, Ohio, in Production Room Two: On or about August 2, 2019, the employer did not ensure employees were adequately trained on the Grote Pepperoni specific energy control procedures. Employees tasked with the performance of activities such as, but not limited to, cleaning of the Grote Peperoni Machine and blade guides were exposed to amputation and caught in hazard in that the equipment was not adequately de-energized.