Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1412830.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,127.00
Current Penalty: $13,127.00
Issuance Date: 12/10/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 01/29/2020
Gravity: 10
Report ID: 0214500
Contest Date: 12/13/2019
Final Order: 09/04/2020
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 09/04/2020 | $13,127.00 | 01/29/2020 | Serious | |
| Penalty | C: Contested | 08/20/2020 | $13,127.00 | 01/29/2020 | Serious | |
| Penalty | Z: Issued | 12/10/2019 | $13,127.00 | 01/29/2020 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by rotating parts: a) Mozzarella Cheese Area: The protective grid located above the hopper section of the SP24 automatic Dima molding machine was equipped with inadequate guarding. The interlock guard had an opening greater than 10 inches, thus exposing employees to an amputation hazard from rotating augers, on or about 7/2/19 and 7/24/19.
Translate