Violation Detail
Standard Cited: 19100134 F01 Respiratory Protection.
Inspection Nr: 1398405.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,419.00
Current Penalty: $10,419.00
Issuance Date: 09/13/2019
Nr Instances: 1
Nr Exposed: 23
Abatement Date: 09/25/2019
Gravity: 5
Report ID: 0111700
Contest Date:
Final Order: 10/07/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/07/2019 | $10,419.00 | 09/25/2019 | Serious | |
Penalty | Z: Issued | 09/13/2019 | $10,419.00 | 09/25/2019 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): Location: To include but not limited to clothing storage area, rug area, pet area, bird seed area, shelving in cleaning area, gardening area, trailer and employee break room. On or about May 3, 2019 employees required to use N95 respirators were not provided fit testing prior to use.