Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1390332.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $9,282.00
Current Penalty: $4,641.00
Issuance Date: 06/11/2019
Nr Instances: 2
Nr Exposed: 3
Abatement Date:
Gravity: 10
Report ID: 0521100
Contest Date:
Final Order: 06/28/2019
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/28/2019 | $4,641.00 | Serious | ||
| Penalty | Z: Issued | 06/11/2019 | $9,282.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. (a) On or about April 1, 2019, Eaton Leonard (Model: VB 42 Elec, S/N: VB 42 Elec RH 861100 LSB10/13) tube bender with an Eyefence (SZ-015) area scanner did not provide guarding to prevent the operator from having any part of the body in the danger zone during operation. (b) On or about April 2, 2019, the Mazak Quick Turn (Model: QT N 20 Chucker, S/N: 115913) had the malfunctioning door interlock which allowed the machine to operate with the door to open during operation and the loading/unloading operation.
Translate