Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
This violation item has been deleted.
Inspection Nr: 1389341.015
Citation: 01002
Citation Type: Serious
Abatement Status:
Initial Penalty: $13,260.00
Current Penalty: $0.00
Issuance Date: 06/04/2019
Nr Instances: 47
Nr Exposed: 50
Abatement Date: 06/24/2019
Gravity: 10
Report ID: 0522300
Contest Date: 07/02/2019
Final Order: 10/26/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 10/26/2020 | $0.00 | 06/24/2019 | Serious | |
Penalty | C: Contested | 07/05/2019 | $13,260.00 | 06/24/2019 | Serious | |
Penalty | Z: Issued | 06/04/2019 | $13,260.00 | 06/24/2019 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks; On or about March 29, 2019 the employer failed to ensure that effective machine guarding was in place on the private label swab machines used in the facility. The access doors to the cotton swab stick hopper were able to be opened by employees during operation. This exposes employees to the pinch point of the hopper feed wheel.