Violation Detail
Standard Cited: 19100333 B02 II B Selection and use of work practices
Inspection Nr: 1384331.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,525.00
Current Penalty: $5,967.50
Issuance Date: 03/25/2019
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 05/09/2019
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 04/16/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/16/2019 | $5,967.50 | 05/09/2019 | Serious | |
| Penalty | Z: Issued | 03/25/2019 | $8,525.00 | 05/09/2019 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.333(b)(2)(ii)(B): The circuits and equipment to be worked on were not disconnected from all electric energy sources: On or about 03/10/2019 and prior dates, Delmar Gardens of Chesterfield, located at 14855 N. Outer 40 Road, Chesterfield, MO, during blade changing of the robot coupe Blixer 6 blender, the blender had not been disconnected from its electrical source. The blade changes had been performed with the blender plugged into its electrical receptacle source.