Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1381093.015
Citation: 01002
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $13,260.00
Current Penalty: $13,260.00
Issuance Date: 04/03/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 05/20/2019
Gravity:
Report ID: 0522000
Contest Date:
Final Order: 04/26/2019
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/26/2019 | $13,260.00 | 05/20/2019 | Other | |
| Penalty | Z: Issued | 04/03/2019 | $13,260.00 | 05/20/2019 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; a)On 2/27/2019 the employer did not provide specific procedures for securing energy sources such as but not limited to kinetic energy for the Marquip Corrugator. An employee was utilizing a grinder with a polisher attachment (Dewalt 4.5 angle grinder Model # D28402) on the rollers of the corrugator, this caused the rollers to free spin, as the employee applied pressure on the grinder the employee's hand slipped, causing the hand to go in between two of the rollers.
Translate