Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1377862.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,630.00
Current Penalty: $4,641.00
Issuance Date: 07/31/2019
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 08/26/2019
Gravity: 5
Report ID: 0317300
Contest Date:
Final Order: 08/22/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/22/2019 | $4,641.00 | 08/26/2019 | Serious | |
| Penalty | Z: Issued | 07/31/2019 | $6,630.00 | 08/26/2019 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: a) 1617 Matassino Road, New Castle, Delaware - On or about February 11, 2019, the employer did not ensure that all energy sources were isolated when an Ariens Snow blower was being maintained in the field resulting in the unexpected startup of the machine resulting in an employee suffering an injury.
Translate