Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1377473.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,347.00
Current Penalty: $2,500.00
Issuance Date: 03/06/2019
Nr Instances: 1
Nr Exposed: 9
Abatement Date: 04/10/2019
Gravity: 1
Report ID: 0830500
Contest Date:
Final Order: 03/21/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/21/2019 | $2,500.00 | 04/10/2019 | Serious | |
| Penalty | Z: Issued | 03/06/2019 | $4,347.00 | 04/10/2019 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) Glenwood Hot Springs Lodge and Pool Inc., at 401 N River Rd., Glenwood Springs CO: On 2/8/2019 the employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed. The employer maintained equipment subject to lockout tagout including, but not limited to, the spring pump and the circulation pump. This condition exposed employees to amputation hazards.