Violation Detail
Standard Cited: 19100178 N07 III Powered industrial trucks.
Inspection Nr: 1370935.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,304.00
Current Penalty: $2,360.00
Issuance Date: 04/16/2019
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 05/03/2019
Gravity: 5
Report ID: 0111500
Contest Date:
Final Order: 05/14/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/14/2019 | $2,360.00 | 05/03/2019 | Serious | |
Penalty | Z: Issued | 04/16/2019 | $5,304.00 | 05/03/2019 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.178(n)(7)(iii): On all grades the load and load engaging means shall be tilted back if applicable, and raised only as far as necessary to clear the road surface. Facility: The load and load engaging means of the Yale powered industrial truck (PIT), SN A810N04039V, were raised far more than as necessary to clear the road surface. On or about January 11, 2019, the above PIT while carrying a load tipped over to a side while the operator was making a sharp turn with the load engaging mean was raised far more than it was necessary, and the operator sustained injuries from the incident.