Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1367413.015
Citation: 01002
Citation Type: Serious
Abatement Status:
Initial Penalty: $11,934.00
Current Penalty: $0.00
Issuance Date: 03/14/2019
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 04/09/2019
Gravity: 10
Report ID: 0418100
Contest Date:
Final Order: 04/03/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/03/2019 | $0.00 | 04/09/2019 | Serious | |
| Penalty | Z: Issued | 03/14/2019 | $11,934.00 | 04/09/2019 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about 12/19/2018, at the planer mill equipment located at 5863 Washington Road, Appling, GA: Where employees performed servicing and maintenance activities on equipment including, but not limited to, banding/strapper equipment line. The employer failed to conduct periodic inspection of their written energy control procedures at least annually to protect the authorized employees from a caught-in and amputation hazards.
Translate