Violation Detail
Standard Cited: 19100147 D05 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1361266.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,260.00
Current Penalty: $10,608.00
Issuance Date: 04/30/2019
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 06/03/2019
Gravity: 10
Report ID: 0625700
Contest Date:
Final Order: 05/16/2019
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/16/2019 | $10,608.00 | 06/03/2019 | Serious | |
| Penalty | Z: Issued | 04/30/2019 | $13,260.00 | 06/03/2019 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: On or about November 18, 2018, in the Green End Area, the employer failed to ensure hydraulic energy was relieved from hydraulic cylinders on the upper roll before removal during maintenance activities.