Violation Detail
Standard Cited: 19260251 B01 Rigging equipment for material handling.
Inspection Nr: 1346216.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,842.00
Current Penalty: $1,819.00
Issuance Date: 03/07/2019
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 06/18/2019
Gravity: 5
Report ID: 0111100
Contest Date: 03/29/2019
Final Order: 07/08/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 07/08/2019 | $1,819.00 | 06/18/2019 | Serious | |
| Penalty | C: Contested | 04/08/2019 | $2,842.00 | 03/19/2019 | Serious | |
| Penalty | Z: Issued | 03/07/2019 | $2,842.00 | 03/19/2019 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.251(b)(1): Welded alloy steel chain sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and sling manufacturer: Barn - The employer used welded alloy steel chain slings to pull and lift sections of the barn floor with no identification tags stating size, grade, rated capacity, and sling manufacturer.