Violation Detail
Standard Cited: 19100219 B01 Mechanical power-transmission apparatus.
Inspection Nr: 1332491.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,934.00
Current Penalty: $10,500.00
Issuance Date: 11/28/2018
Nr Instances: 31
Nr Exposed: 25
Abatement Date: 01/14/2019
Gravity: 10
Report ID: 0419400
Contest Date:
Final Order: 12/27/2018
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | P: Petition to Mod Abatement | $10,500.00 | 01/14/2019 | Serious | ||
| Penalty | I: Informal Settlement | 12/27/2018 | $10,500.00 | 01/14/2019 | Serious | |
| Penalty | Z: Issued | 11/28/2018 | $12,934.00 | 01/14/2019 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.219(b)(1): Flywheel(s) with parts seven feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv): (a) Centerfire Loading Department - On or about July 19, 2018 rotating hand wheels on Parker and Manurhin centerfire loaders were not guarded.