Violation Detail
Standard Cited: 19100147 C07 III A The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1332130.015
Citation: 01002
Citation Type: Serious
Abatement Date: 10/04/2018 2
Initial Penalty: $11,086.00
Current Penalty: $0.00
Issuance Date: 09/10/2018
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 5
Report ID: 0317500
Contest Date: 10/05/2018
Final Order: 03/04/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/04/2019 | $0.00 | 10/04/2018 | Serious | |
Penalty | C: Contested | 10/10/2018 | $11,086.00 | 10/04/2018 | Serious | |
Penalty | Z: Issued | 09/10/2018 | $11,086.00 | 10/04/2018 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(7)(iii)(A): Retraining was not provided for authorized and affected employees when there was a change in their job assignments, a change in machines, equipment or processes that presented a new hazard, or when there was a change in the energy control procedures: (a) Facility, Assembly Area, 71 Progress Avenue, Cranberry Township, PA: On or about July 20, 2018 retraining had not been provided for authorized and/or affected employees who had a change in their work assignment that included servicing equipment to ensure they understood the process and procedures of the control of energy for equipment used.