Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1325657.015
Citation: 01002
Citation Type: Serious
Abatement Date: 11/05/2018 2
Initial Penalty: $12,934.00
Current Penalty: $9,053.80
Issuance Date: 08/20/2018
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC): C
Gravity: 10
Report ID: 0112000
Contest Date:
Final Order: 09/20/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/20/2018 | $9,053.80 | 11/05/2018 | Serious | |
Penalty | Z: Issued | 08/20/2018 | $12,934.00 | 10/05/2018 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): FACILITY On, or about July 12, 2018, the NIIGATA D, CNC milling machine had a disabled interlock. The enclosure doors were able to be opened during operation, allowing access to the rotating point of operation.