Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1320688.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $9,959.00
Current Penalty: $9,959.00
Issuance Date: 09/28/2018
Nr Instances: 1
Nr Exposed: 4
Abatement Date:
Gravity: 10
Report ID: 0112000
Contest Date:
Final Order: 10/29/2018
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 09/28/2018 | $9,959.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: A. Extruding Department, Line 1: On or about June 6, 2018 and times prior thereto, the SMI light curtain provided at the finish end of the extruding line was not operational. The electrical power cord had sustained damage during the movement of equipment. No pre-shift inspection had been done to ensure that the presence sensing device was operational.