Violation Detail
Standard Cited: 19260451 C01 General requirements.
Inspection Nr: 1310887.015
Citation: 01002
Citation Type: Serious
Abatement Date: 06/26/2018 2
Initial Penalty: $3,880.00
Current Penalty: $2,000.00
Issuance Date: 06/20/2018
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): A
Gravity: 10
Report ID: 0625400
Contest Date:
Final Order: 07/17/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/17/2018 | $2,000.00 | 06/26/2018 | Serious | |
Penalty | Z: Issued | 06/20/2018 | $3,880.00 | 06/26/2018 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph. On or about April 14, 2018, and in times prior thereto, workers were using a scaffold that was 29 inches wide to access elevations of up to 18 feet without attaching the required outriggers. This exposed the drywall workers to a fall hazard of over 10 feet, located at the outlet mall, space #1045.