Violation Detail
Standard Cited: 19100147 C01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1298997.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,880.00
Current Penalty: $2,328.00
Issuance Date: 08/30/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 10/18/2018
Gravity: 10
Report ID: 0420600
Contest Date:
Final Order: 09/27/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/27/2018 | $2,328.00 | 10/18/2018 | Serious | |
| Penalty | Z: Issued | 08/30/2018 | $3,880.00 | 10/18/2018 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a. The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections for the maintenance of the McCloskey Trommel model 621RE including the clearing of jams of construction and demolition landfill process debris.