Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1295445.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,989.00
Current Penalty: $2,743.95
Issuance Date: 05/14/2018
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 06/06/2018
Gravity: 1
Report ID: 0728500
Contest Date:
Final Order: 06/08/2018
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/08/2018 | $2,743.95 | 06/06/2018 | Serious | |
| Penalty | Z: Issued | 05/14/2018 | $4,989.00 | 06/06/2018 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: In an examination of program elements determined that periodic inspections of energy control procedures were not accomplished and certified. Specifically, reviews were not conducted to determine if listed steps were still adequate, if any changes had occurred, or if employees had acquired the knowledge needed to effectively isolate energy sources.