Violation Detail
Standard Cited: 19100169 B03 IV Air receivers.
Inspection Nr: 1293033.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,654.00
Current Penalty: $3,500.00
Issuance Date: 04/11/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 05/29/2018
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 05/09/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/09/2018 | $3,500.00 | 05/29/2018 | Serious | |
Penalty | Z: Issued | 04/11/2018 | $5,654.00 | 05/29/2018 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.169(b)(3)(iv): Safety valve(s) on compressed air receiver(s) were not tested at frequently regular intervals to determine if they were in good operating condition: In the lower building, safety relief valve(s), such as on the air receiver at die cast machine 05DC031, were not tested at regular intervals; there were no records of testing. Abatement documentation is required for this violation.