Violation Detail
Standard Cited: 19260652 A01 Requirements for protective systems.
Inspection Nr: 1292788.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $12,934.00
Current Penalty: $0.00
Issuance Date: 02/15/2018
Nr Instances: 1
Nr Exposed: 4
Abatement Date:
Gravity: 10
Report ID: 0316700
Contest Date: 03/12/2018
Final Order: 04/17/2025
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 04/17/2025 | $0.00 | Serious | ||
| Penalty | C: Contested | 03/13/2018 | $12,934.00 | Serious | ||
| Penalty | Z: Issued | 02/15/2018 | $12,934.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) and (c). (a) Site 79 & 32 in Lancaster, PA - Employees entered a trench 13 feet deep that was not provided with adequate sloping and benching system or a supported system, shield system, or other protective systems thereby exposing employees to a trench collapsed, on or about February 1, 2018. No abatement certification or documentation required.