Violation Detail
Standard Cited: 19260754 A Structural steel assembly.
Inspection Nr: 1290537.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,174.00
Current Penalty: $2,000.00
Issuance Date: 04/25/2018
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 05/01/2018
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 05/25/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/25/2018 | $2,000.00 | 05/01/2018 | Serious | |
Penalty | Z: Issued | 04/25/2018 | $5,174.00 | 05/01/2018 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.754(a): Structural stability shall be maintained at all times during the erection process. On November 13, 2017 during the initial erection of structural steel columns, open web joist girders and open web tie joists along B line, open web joist girders were connected to the columns from 1 to 4 lines prior to any open web tie joist being connected to the tilt wall panels at A line at which time structural stability of the columns, open web joist girders and open web tie joist was not maintained subsequently causing the head weight of the open web girders not to be adequately supported by the columns within 6 inch column sleeves, resulting in the erected columns and connected open web joist girders collapsing to the inside of the building at C line exposing employees to a struck by hazard potential of collapsing structural steel.