Violation Detail
Standard Cited: 19100119 D03 I Process safety management of highly hazardous chemicals.
Inspection Nr: 1288654.015
Citation: 01002
Citation Type: Other
Abatement Status: Quick Fix
Initial Penalty: $4,005.00
Current Penalty: $0.00
Issuance Date: 04/09/2018
Nr Instances: 6
Nr Exposed: 8
Abatement Date:
Gravity:
Report ID: 1032500
Contest Date:
Final Order: 05/04/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/04/2018 | $0.00 | Other | ||
Penalty | Z: Issued | 04/09/2018 | $4,005.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.119(d)(3)(i): 29 CFR 1910.119(d)(3)(i): Process safety information pertaining to the equipment in the process did not include the elements specified in 29 CFR 1910.119(d)(3)(i)(A) through (H): (a) Refrigeration Building: On or about January 8, 2018 and at times prior, the oil return lines on compressor 200 had isolation valve B31 identified as B37 on the drawings, solenoid valve/strainer unit B32 identified as B37 on the drawings, and solenoid valve/strainer unit B38 identified as B32 on the drawings. (b) Refrigeration Building: On or about January 8, 2018 and at times prior, the oil return lines on compressor 300 had isolation valve B31 identified as B37 on the drawings, solenoid valve/strainer unit B32 identified as B37 on the drawings, and solenoid valve/strainer unit B38 identified as B32 on the drawings. (c) Refrigeration Building: On or about January 8, 2018 and at times prior, the oil return lines on compressor 400 had isolation valve B31 identified as B37 on the drawings, solenoid valve/strainer unit B32 identified as B37 on the drawings, and solenoid valve/strainer unit B38 identified as B32 on the drawings. (d) Refrigeration Building: On or about January 8, 2018 and at times prior, the oil return lines on compressor 500 had isolation valve B31 identified as B37 on the drawings, solenoid valve/strainer unit B32 identified as B37 on the drawings, and solenoid valve/strainer unit B38 identified as B32 on the drawings. (e) Refrigeration Building: On or about January 8, 2018 and at times prior, the oil return lines on compressor 600 had isolation valve B31 identified as B37 on the drawings, solenoid valve/strainer unit B32 identified as B37 on the drawings, and solenoid valve/strainer unit B38 identified as B32 on the drawings. (f) Refrigeration Building: On or about January 8, 2018 and at times prior, the oil return lines on compressor 700 had isolation valve B31 identified as B37 on the drawings, solenoid valve/strainer unit B32 identified as B37 on the drawings, and solenoid valve/strainer unit B38 identified as B32 on the drawings. Note: Abatement certification is not required for this item. Fixed at the time of inspection.