Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1275029.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/26/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 05/17/2018
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 05/21/2018
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/21/2018 | $0.00 | 05/17/2018 | Serious | |
| Penalty | Z: Issued | 04/26/2018 | $0.00 | 05/17/2018 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Swan Lake Research Farm; On or about October 31, 2017, the John Deere 9750 STS Combine was not locked out prior to performing servicing and maintenance including clearing jams.
Translate