Violation Detail
Standard Cited: 19261408 A02
Inspection Nr: 1272605.015
Citation: 01002
Citation Type: Serious
Abatement Status: Not Completed - AD Discretion
Initial Penalty: $12,934.00
Current Penalty: $12,934.00
Issuance Date: 04/04/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 04/23/2018
Gravity: 10
Report ID: 0418800
Contest Date:
Final Order: 05/01/2018
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 04/04/2018 | $12,934.00 | 04/23/2018 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.1408(a)(2): Determine if any part of the equipment, load line or load (including rigging and lifting accessories), if operated up to the equipment's maximum working radius in the work zone, could get closer than 20 feet to a power line. If so, the employer must meet the requirements in Option (1), Option (2), or Option (3) of this section, as follows: On or about October 6, 2017, at the above addressed jobsite, the employer did not determine if any part of the crane, load line, or load (light pole) could get closer then 20 feet to a 13.2 KV power line, exposing the employees to a shock hazard.
Translate