Violation Detail
Standard Cited: 19100219 F03 Mechanical power-transmission apparatus.
Inspection Nr: 1268991.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,934.00
Current Penalty: $9,054.00
Issuance Date: 01/08/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 09/30/2018
Gravity: 10
Report ID: 0418300
Contest Date: 02/05/2018
Final Order: 09/20/2018
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | J: ALJ Decision | 09/20/2018 | $9,054.00 | 09/30/2018 | Serious | |
| Penalty | C: Contested | 02/06/2018 | $12,934.00 | 01/17/2018 | Serious | |
| Penalty | Z: Issued | 01/08/2018 | $12,934.00 | 01/17/2018 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: (a) On or about 10/4/2017 - Evisceration Line 1, the Presenter Chain sprocket wheel and chain was not enclosed at Stands 1, 2, and 3.