Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1266349.015
Citation: 01002
Citation Type: Serious
Abatement Date: 11/27/2018 2
Initial Penalty: $12,934.00
Current Penalty: $9,054.00
Issuance Date: 03/15/2018
Nr Instances: 3
Nr Exposed: 9
Related Event Code (REC): A
Gravity: 10
Report ID: 0728900
Contest Date: 03/20/2018
Final Order: 01/11/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/11/2019 | $9,054.00 | 11/27/2018 | Serious | |
Penalty | C: Contested | 05/17/2018 | $12,934.00 | 03/30/2018 | Serious | |
Penalty | Z: Issued | 03/15/2018 | $12,934.00 | 03/30/2018 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees had the knowledge and skills required for the safe application, usage and removal of energy control devices: The employer is failing to train employees on the struck by and crushing hazards associated with servicing and maintaining equipment with stored energy. This was most recently documented on September 27, 2017 during the inspection of the facility located at 105 N. Main St. Wakefield, NE; where the employer has inadequately trained employees operating, troubleshooting and repairing equipment such as but not limited to dock levelers.