Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1254851.015
Citation: 01002
Citation Type: Serious
Abatement Date: 10/24/2017 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/27/2017
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0522900
Contest Date:
Final Order: 10/25/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 09/27/2017 | $0.00 | 10/24/2017 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(4)(i) as required by 1960.8(b): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about August 11, 2017, the employer did not develop procedures to control and isolate hazardous energy exposing employees to mechanical and hydraulic energy hazards while performing servicing and/or maintenance work on machines or equipment such as but not limited to 12 inch Crossley Net Lifter.