Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1246450.015
Citation: 01002
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $12,675.00
Current Penalty: $9,250.00
Issuance Date: 09/12/2017
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 10/30/2018
Gravity: 10
Report ID: 0522500
Contest Date: 09/27/2017
Final Order: 09/20/2018
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | J: ALJ Decision | 09/20/2018 | $9,250.00 | 10/30/2018 | Other | |
| Penalty | C: Contested | 09/29/2017 | $12,675.00 | 09/29/2017 | Serious | |
| Penalty | Z: Issued | 09/12/2017 | $12,675.00 | 09/29/2017 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d)(2): Machine or equipment shutdown. The machine or equipment shall be turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage. On July 5, 2017, in the Facer Department, the employer did not ensure that an employee complied with the employer's policy requiring the equipment to be shut down and de-energized prior to allowing employees to preform shear pin changes on the Landis facer machine (serial #10309) for removing a pin.
Translate