Violation Detail
Standard Cited: 19260451 B05 I General requirements.
Inspection Nr: 1242380.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $2,987.00
Current Penalty: $2,987.00
Issuance Date: 10/19/2017
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 5
Report ID: 0111400
Contest Date:
Final Order: 11/14/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 10/19/2017 | $2,987.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length extended over its support more than 12 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end. Jobsite: Carpenters bracket scaffolding at front of building, north side. A scaffold plank extended over its support by approximately five feet. No provisions had been made to secure the plank and prevent the cantilevered portion from falling if an employee stepped on it.