Violation Detail
Standard Cited: 19100219 F01 Mechanical power-transmission apparatus.
Inspection Nr: 1238604.015
Citation: 01002
Citation Type: Serious
Abatement Date: 07/19/2017 2
Initial Penalty: $8,963.00
Current Penalty: $5,378.00
Issuance Date: 06/29/2017
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): C
Gravity: 5
Report ID: 0626600
Contest Date: 07/26/2017
Final Order: 04/26/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | R: Review Commission | 04/26/2018 | $5,378.00 | 07/19/2017 | Serious | |
Penalty | C: Contested | 07/26/2017 | $8,963.00 | 07/19/2017 | Serious | |
Penalty | Z: Issued | 06/29/2017 | $8,963.00 | 07/19/2017 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii). On or about June 09, 2017, in the production area, where employees were exposed to a caught-by hazard when operating and walking by threading machine #14 without a guard on the gear.