Violation Detail
Standard Cited: 19100219 F03 Mechanical power-transmission apparatus.
Inspection Nr: 1221320.015
Citation: 01002
Citation Type: Other
Abatement Date: 3
Initial Penalty: $4,310.00
Current Penalty: $0.00
Issuance Date: 09/19/2017
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity:
Report ID: 0523400
Contest Date: 10/13/2017
Final Order: 02/12/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/12/2018 | $0.00 | Other | ||
Penalty | C: Contested | 10/17/2017 | $4,310.00 | Serious | ||
Penalty | Z: Issued | 09/19/2017 | $4,310.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above the floor or platform were not enclosed: (a) In the southwest corner of the production shop, a 50 d.p. chain driven by a 50B11 sprocket and being used to provide motion to the 5 gal. bucket mixer was not protected by guarding exposing employees to caught-in, pinch point and crushing hazards.