Violation Detail
Standard Cited: 19100146 F08 Permit-required confined spaces
This violation item has been deleted.
Inspection Nr: 1220605.015
Citation: 01002
Citation Type: Serious
Abatement Status:
Initial Penalty: $12,675.00
Current Penalty: $0.00
Issuance Date: 09/08/2017
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 09/20/2017
Gravity: 10
Report ID: 0627500
Contest Date: 09/27/2017
Final Order: 07/18/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 07/18/2018 | $0.00 | 09/20/2017 | Serious | |
Penalty | C: Contested | 09/28/2017 | $12,675.00 | 09/20/2017 | Serious | |
Penalty | Z: Issued | 09/08/2017 | $12,675.00 | 09/20/2017 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.146(f)(8): The entry permit that documented compliance and authorized entry to a permit space did not identify the measures used to isolate the permit space and to eliminate or control permit space hazards before entry. On March 27, 2017, the employer or his representative did not ensure that the entry permit identified the measures used to isolate the permit space and to eliminate or control permit space hazards such as but not limited to the agitators. This condition exposed employees to caught-in and struck-by hazards.