Violation Detail
Standard Cited: 19100212 B General requirements for all machines.
This violation item has been deleted.
Inspection Nr: 1212070.015
Citation: 01002
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $5,975.00
Current Penalty: $0.00
Issuance Date: 05/08/2017
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 1
Report ID: 0216000
Contest Date: 05/25/2017
Final Order: 01/14/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 01/14/2019 | $0.00 | Serious | ||
Penalty | C: Contested | 05/31/2017 | $5,975.00 | Serious | ||
Penalty | Z: Issued | 05/08/2017 | $5,975.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard: