Violation Detail
Standard Cited: 19260452 J01 Additional requirements applicable to specific types of scaffolds.
Inspection Nr: 1208987.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,873.00
Current Penalty: $7,098.00
Issuance Date: 05/31/2017
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 06/12/2017
Gravity: 10
Report ID: 0523400
Contest Date:
Final Order: 06/21/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/21/2017 | $7,098.00 | 06/12/2017 | Serious | |
| Penalty | Z: Issued | 05/31/2017 | $8,873.00 | 06/12/2017 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.452(j)(1): 29 CFR 1926.452(j)(1): Pump jack brackets, braces, and accessories were not fabricated from metal plates and angles. Each pump jack bracket did not have two positive gripping mechanisms to prevent any failure or slippage. (a) The employer did not ensure that the two positive gripping mechanisms on the Hydro-Mobile scaffold were working properly to prevent failure or slippage. This condition exposed employees to a collapse of the scaffold and a 40 foot fall hazard.