Violation Detail
Standard Cited: 19260502 D15 Fall protection systems criteria and practices.
Inspection Nr: 1207563.015
Citation: 01002
Citation Type: Serious
Abatement Date: 08/14/2017 2
Initial Penalty: $2,716.00
Current Penalty: $1,358.00
Issuance Date: 07/19/2017
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC):
Gravity: 5
Report ID: 0420600
Contest Date:
Final Order: 08/09/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/09/2017 | $1,358.00 | 08/14/2017 | Serious | |
Penalty | Z: Issued | 07/19/2017 | $2,716.00 | 08/14/2017 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment were not independent of any anchorage being used to support or suspend platforms and/or were not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached: (a) on the jobsite - employees were exposed to a 9ft,2in fall hazard, in that, three to four employees were attached to one High Visible Rock Solid (model CRPK-anchor) butterfly anchor rated for 5,000 pounds located at the peak of the roof of the main sanctuary building (6:12 slope); observed on or about 2/2/2017.