Violation Detail
Standard Cited: 19100023 C01 Ladders.
Inspection Nr: 1192857.015
Citation: 01002
Citation Type: Serious
Abatement Date: 05/10/2017 2
Initial Penalty: $12,675.00
Current Penalty: $6,338.00
Issuance Date: 04/18/2017
Nr Instances: 4
Nr Exposed: 2
Related Event Code (REC): C
Gravity: 10
Report ID: 0521400
Contest Date:
Final Order: 05/05/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/05/2017 | $6,338.00 | 05/10/2017 | Serious | |
Penalty | Z: Issued | 04/18/2017 | $12,675.00 | 05/10/2017 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides. On or about 23 November 2016, employees retrieving materials from racking systems up to 23 feet above grade were not provided with fall protection by a standard guardrail system or equivalent means while working from platforms supported by "Order Picker" powered industrial trucks. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).