Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1168220.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,471.00
Current Penalty: $8,730.00
Issuance Date: 11/07/2016
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 12/28/2016
Gravity: 10
Report ID: 0626700
Contest Date:
Final Order: 12/06/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/06/2016 | $8,730.00 | 12/28/2016 | Serious | |
Penalty | Z: Issued | 11/07/2016 | $12,471.00 | 11/28/2016 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: At the Agglomeration Department; employees were cleaning a 6000 Rotary Airlock, model PAV-8, administrated number A5 with an unguarded horizontal shaft, exposing employees to caught in hazards.