Violation Detail
Standard Cited: 19100107 B05 I Spray finishing using flammable and combustible materials.
Inspection Nr: 1153231.015
Citation: 01002
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $5,345.00
Current Penalty: $500.00
Issuance Date: 11/30/2016
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 12/29/2016
Gravity:
Report ID: 0521100
Contest Date:
Final Order: 12/14/2016
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/14/2016 | $500.00 | 12/29/2016 | Other | |
Penalty | Z: Issued | 11/30/2016 | $5,345.00 | 12/29/2016 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.107(b)(5)(i): There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained. Filter rolls were not inspected to ensure proper replacement of filter media: a) The manometers for the powder coating and paint standalone spray booths were not operational on June 9, 2016. b) The exhaust duct filtering material was not correctly installed in the powder coating standalone spray booth on June 9, 2016. There were large gaps between the filtering material and the spray booth wall. The large gaps allowed the powder coating material to collect in the exhaust duct.