Violation Detail
Standard Cited: 19260651 C02 Specific Excavation Requirements.
Inspection Nr: 1146510.015
Citation: 01002
Citation Type: Serious
Abatement Status: Quick Fix
Initial Penalty: $2,380.00
Current Penalty: $1,428.00
Issuance Date: 07/29/2016
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 5
Report ID: 0625700
Contest Date:
Final Order: 08/22/2016
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/22/2016 | $1,428.00 | Serious | ||
| Penalty | Z: Issued | 07/29/2016 | $2,380.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.651(c)(2): Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees. On or about 5/18/2016 in the cable tray foundation trench at the worksite located at 6239 Upper Donahue Ferry Road, Pineville, LA; employees were allowed to enter and exit the 4' deep by 6' wide by 22' long trench by jumping in and climbing out at the vertical walls of the trench; thus exposing employees to fall hazards.