Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1112720.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $2,295.00
Current Penalty: $1,721.25
Issuance Date: 02/10/2016
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 1
Report ID: 0215800
Contest Date:
Final Order: 02/15/2016
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/15/2016 | $1,721.25 | Serious | ||
| Penalty | Z: Issued | 02/10/2016 | $2,295.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
9 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a) Throughout the facility, on or about 12/16/15: No periodic inspection was conducted of the energy control procedure to ensure that the procedures and requirements of the standard were being followed. Employees perform servicing and/or maintenance on various machinery or equipment including but not limited to: Plasma Cutter.