Violation Detail
Standard Cited: 19100147 C01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1103321.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,800.00
Current Penalty: $1,960.00
Issuance Date: 02/24/2016
Nr Instances: 1
Nr Exposed: 7
Abatement Date: 03/14/2016
Gravity: 10
Report ID: 0418100
Contest Date:
Final Order: 03/09/2016
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/09/2016 | $1,960.00 | 03/14/2016 | Serious | |
| Penalty | Z: Issued | 02/24/2016 | $2,800.00 | 03/14/2016 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: On or about 11/3/2015 at 915 Tom Miller Road in Bethlehem, GA: An energy control program with specific energy control procedures were not developed where employees were required to perform repairs, maintenance, service, and troubleshoot disabled vehicles.