Violation Detail
Standard Cited: 19100023 C03 Ladders.
Inspection Nr: 1100097.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $3,700.00
Issuance Date: 04/11/2016
Nr Instances: 10
Nr Exposed: 16
Abatement Date: 06/30/2016
Gravity: 10
Report ID: 0728900
Contest Date:
Final Order: 04/28/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/28/2016 | $3,700.00 | 06/30/2016 | Serious | |
Penalty | Z: Issued | 04/11/2016 | $7,000.00 | 05/26/2016 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.23(c)(3): Regardless of height, open-sided floors, walkways, platforms, or runways above or adjacent to dangerous equipment, pickling or galvanizing tanks, degreasing units, and similar hazards were not guarded with a standard railing and toe board: The employer is failing to protect employees from a fall/electrical hazard in that the platform used to access the upper areas of the mold machines was designed/built so that it creates a fall hazard onto electrical equipment at a voltage of 480 volts in the mold machine area. This was most recently documented at 1329 West Highway 6, Holdrege Nebraska on the following 420 Engel Model # EM1320/420T Mold Machines: a. Serial # 189759 b. Serial # 189760 c. Serial # 181185 e. Serial # 181183 f. Serial # 181189 g. Serial # 181187 h. Serial # 177612 I. Serial # 181188 j. Serial # 181186 k. Serial # 178089