Violation Detail
Standard Cited: 19100106 E09 III Flammable liquids.
Inspection Nr: 1099337.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,100.00
Current Penalty: $500.00
Issuance Date: 02/10/2016
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 03/08/2016
Gravity: 1
Report ID: 0213900
Contest Date: 03/11/2016
Final Order: 09/15/2016
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 09/15/2016 | $500.00 | 03/08/2016 | Serious | |
Penalty | C: Contested | 03/14/2016 | $2,100.00 | 03/08/2016 | Serious | |
Penalty | Z: Issued | 02/10/2016 | $2,100.00 | 03/08/2016 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily: a) Rubber department: Cloth rags used to apply Methyl Ethyl Ketone and Vulcatek Rubber Solvent to rubber and/or Viton molds were not disposed of daily into covered metal receptacles, on or about 10/19/15. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.