Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1092367.015
Citation: 01002
Citation Type: Serious
Abatement Date: 11/16/2015 2
Initial Penalty: $7,000.00
Current Penalty: $4,900.00
Issuance Date: 10/21/2015
Nr Instances: 1
Nr Exposed: 6
Related Event Code (REC):
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 12/10/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/10/2015 | $4,900.00 | 11/16/2015 | Serious | |
Penalty | Z: Issued | 10/21/2015 | $7,000.00 | 11/16/2015 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Cardington Yutaka Technologies, Inc. on or about September 09, 2015, at the address of 575 West Main St. Cardington, OH: The employer failed to ensure that employees who are responsible/tasked with service work at or near the point of operation on the Double End Forming Machine (#320052) were adequately evaluated for the skills required for the appropriate application and usage of machine specific energy control procedures. Employees performing service work in an energized condition were exposed to amputation hazards.