Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1090057.015
Citation: 01002
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $7,000.00
Current Penalty: $7,000.00
Issuance Date: 09/30/2015
Nr Instances: 1
Nr Exposed: 9
Abatement Date:
Gravity:
Report ID: 0112600
Contest Date:
Final Order: 10/23/2015
Related Event Code (REC): A;R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/23/2015 | $7,000.00 | Other | ||
| Penalty | Z: Issued | 09/30/2015 | $7,000.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Tube sand filling machine, Anchor an Oldcastle Company, 204 Old Webster Road, Oxford, Massachusetts; The employer did not provide the operators of the tube sand filling machine with guarding to protect them from crushing and amputation hazards at the point of operation of the spout. Employees hold bags with their hands while the spout opens with pneumatic pressure to hold the bag while filling.